[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"project-112906":3},{"id":4,"name":5,"fullName":6,"owner":7,"repo":5,"description":8,"homepage":9,"htmlUrl":9,"language":10,"languages":9,"totalLinesOfCode":9,"stars":11,"forks":12,"watchers":13,"openIssues":14,"contributorsCount":15,"subscribersCount":15,"size":15,"stars1d":15,"stars7d":16,"stars30d":17,"stars90d":15,"forks30d":15,"starsTrendScore":14,"compositeScore":18,"rankGlobal":9,"rankLanguage":9,"license":9,"archived":19,"fork":19,"defaultBranch":20,"hasWiki":21,"hasPages":19,"topics":22,"createdAt":9,"pushedAt":31,"updatedAt":32,"readmeContent":33,"aiSummary":34,"trendingCount":15,"starSnapshotCount":15,"syncStatus":14,"lastSyncTime":35,"discoverSource":36},112906,"neurband","jlcjak\u002Fneurband","jlcjak","Open, minimal sEMG wristband like the Meta Neural Band: 8-ch ADS1298 + nRF52832 BLE, dry gold electrodes on a flex, 3D-printed band. KiCad, FreeCAD, Zephyr, Python, simulations.",null,"Python",64,5,1,2,0,6,7,43.03,false,"main",true,[23,24,25,26,27,28,29,30],"bci","emg","kicad","neural-interface","nrf52","open-hardware","semg","wearable","2026-11-17 22:22:19","2026-11-22 00:32:49","# neurband\n\n**An open, minimal sEMG wristband, like the Meta Neural Band.** Eight bipolar surface-EMG channels around the\nwrist, a 24-bit biopotential front end, Bluetooth LE, and a module the size of a small watch face — designed\nfrom first principles to record data good enough to train gesture models, and cheap enough to just build.\n\n![neurband on the wrist](docs\u002Fmedia\u002Fhero_arm_wide_r2.jpg)\n\n> **Status: design complete, not yet built.** Schematics, both PCBs (DRC-clean), mechanics, firmware\n> (builds and links, untested on hardware), recorder and analysis code are done; everything below that says\n> \"simulated\" or \"estimated\" has not been measured on a real board yet. See [what's next](#status-and-next-steps).\n\n| | |\n|---|---|\n| Channels | 8 bipolar (P–N 20 mm along the forearm) + a driven bias pad in every pod |\n| Front end | TI ADS1298, 24 bit, gain 6, 4 kSPS acquisition, ~1.2 µVrms (20–850 Hz) |\n| Electrodes | 24 dry 6.5 mm ENIG gold pads on a 2-layer polyimide flex, foam-backed, 1 mm proud |\n| Radio | nRF52832, BLE 5 2M PHY, printed antenna; 2 kSPS × 8 ch, 16-bit stream |\n| IMU | LSM6DSL accel + gyro, 208 Hz |\n| Power | 401223-class LiPo, about 130 mAh, ~12 h streaming (estimate); 2-pin magnetic charging connector in the module's end wall (charge with the band off the wrist) |\n| Module | 31.6 × 37.1 × 9.65 mm body (48 mm across the strap bars), tapered and crowned, one size for 145–180 mm wrists |\n| Strap | 20 mm hook-and-loop watch strap through two thick bars moulded into the base; the electrode pods snap onto it |\n| Cost | ≈ $290–350 for a first build: 5 boards (2 assembled), 5 flexes, prints and off-the-shelf parts ([breakdown](docs\u002Frev_c\u002Fcost.md)) |\n\n## Gallery\n\n| | |\n|---|---|\n| ![](docs\u002Fmedia\u002Fturntable_r2.gif) | ![](docs\u002Fmedia\u002Fhero_dark_r2.jpg) |\n| ![](docs\u002Fmedia\u002Fhero_crop_r2.jpg) | ![](docs\u002Fmedia\u002Fband_product_r2.jpg) |\n| ![](docs\u002Fmedia\u002Fxray_r2.jpg) | ![](docs\u002Fmedia\u002Fexploded_r2.jpg) |\n| ![](docs\u002Fmedia\u002Fflatlay_r2.jpg) | ![](docs\u002Fmedia\u002Fpods_inside_r2.jpg) |\n| ![](docs\u002Fmedia\u002Fpcb_top_r2.jpg) | ![](docs\u002Fmedia\u002Fflex_detail_r2.jpg) |\n\nThe boards as laid out (KiCad renders, main board top and bottom; 28.7 × 27 mm):\n\n| | |\n|---|---|\n| ![](docs\u002Fmedia\u002Fboard_top_r2.png) | ![](docs\u002Fmedia\u002Fboard_bottom_r2.png) |\n\nAll four copper layers (`python3 tools\u002Fcopper_layers.py`):\n\n![four copper layers of the main board](docs\u002Fmedia\u002Fboard_layers_r2.png)\n\nA 1080 × 1350 turntable video is in [docs\u002Fmedia\u002Fturntable_r2.mp4](docs\u002Fmedia\u002Fturntable_r2.mp4).\nAll images are rendered from the real CAD and KiCad files with `python3 render\u002Fmake_renders.py` (Blender Cycles);\nsee [docs\u002Frenders.md](docs\u002Frenders.md).\n\n## How it works\n\n```\n skin ─ 8 pods × (P, bias, N) gold pads ─ polyimide flex (GND-shielded) ─ 20-pin FPC\n   └─ main board 28.7 × 27 mm, 4 layers, one-sided assembly\n        ADS1298 ─ 16 × 10 kΩ inputs, bias amp (1 MΩ‖4.7 nF → all middle pads), filtered AVDD\u002F2 reference\n          │ SPI\n        nRF52832 ─ printed 2.4 GHz antenna ─ BLE ─► nRF52840 USB dongle ─► host\u002Fneurband_ble.py ─► .npz\n          ├ LSM6DSL IMU, button (wake\u002Fmarker), LED\n        LiPo ─ XC6206 3.3 V ─ RC filter ─ AVDD          magnetic charge connector ─ TP4054\n```\n\nLike Meta's research band (*A generic non-invasive neuromotor interface for\nhuman-computer interaction*, Nature 2025), it has what matters: bipolar gold contacts 20 mm apart along the forearm, µV-level noise,\n2 kHz data. It drops what only costs money: per-pod amplifiers, 16 channels, custom electrodes.\nThe reasoning, decision by decision, is in [docs\u002Frev_c\u002FREADME.md](docs\u002Frev_c\u002FREADME.md).\n\n## The science, checked before building\n\nFour independent reviews and simulations went into this design:\n\n- **Signal chain** ([docs\u002Fscience\u002Fsignal_chain.md](docs\u002Fscience\u002Fsignal_chain.md)): noise budget, dry-contact\n  impedance, mains pickup, sampling and BLE throughput, with pass\u002Ffail bench gates.\n- **Circuit simulation** ([docs\u002Fscience\u002Fsimulations.md](docs\u002Fscience\u002Fsimulations.md), ngspice): bias-loop\n  stability (57° worst-case phase margin), mains residual (≤ 1.5 µV on battery), RF filtering, radio-burst\n  coupling — which is why the bias reference is filtered.\n- **Forearm volume-conductor model** ([docs\u002Fscience\u002Femg_forward_model.md](docs\u002Fscience\u002Femg_forward_model.md)):\n  a 3-D finite-difference model of the distal forearm (bones, muscles, fat, skin, anisotropic muscle), lead\n  fields of all 8 channels, travelling motor-unit action potentials. 8 channels separate single muscles at\n  98–100 %; pad size, spacing and band rotation are quantified.\n- **Data & models** ([docs\u002Fscience\u002Fdata_and_models.md](docs\u002Fscience\u002Fdata_and_models.md)): what 8-channel wrist\n  EMG can decode, how to use Meta's open datasets, a first-week recording protocol, and a working pipeline.\n\n| | |\n|---|---|\n| ![](docs\u002Fscience\u002Ffigures\u002Femgfwd_cross_section.png) | ![](docs\u002Fscience\u002Ffigures\u002Femgfwd_skin_map.png) |\n\n**Honest expectations** (per user, with calibration): 6–8 hand\u002Fwrist postures at ~90–98 %, pinches and thumb\nswipes at ~75–90 %, 2-axis wrist control. Not expected: models that work across people without calibration,\ntyping, fluent handwriting.\n\n## Build one\n\n**Build guide: [docs\u002Fbuild\u002Fassembly.md](docs\u002Fbuild\u002Fassembly.md)**: the shopping list, the prints, ten\nillustrated steps, troubleshooting and the tests to run on a first band (also as a\n[PDF](docs\u002Fbuild\u002Fneurband_build_manual.pdf)). There is also a 36 s\n[assembly animation](docs\u002Fmedia\u002Fassembly_r2.mp4).\n\nA first prototype costs around $300 (≈ $290–350 for five main boards with two assembled, five electrode flexes,\nthe prints and the off-the-shelf parts; [breakdown](docs\u002Frev_c\u002Fcost.md)). Most of it is the ADS1298 and the\nfab's assembly fees.\n\n1. **Order** two things:\n   - the assembled main board, the electrode flex and the prints, with **Buy it** in Backplane\n     (`boards\u002Fneurband_c\u002FORDERING.md`, `boards\u002Fneurband_c_flex\u002FORDERING.md`, `mech\u002Frev_c\u002F*.fab.json`);\n   - about EUR 75 of off-the-shelf parts ([docs\u002Fbuild\u002Fsourcing.md](docs\u002Fbuild\u002Fsourcing.md)): a 20 mm\n     hook-and-loop watch strap, 6 mm foam dots, a 401223 LiPo, a 2-pin magnetic charging connector and\n     cable, a Pico 2 as the SWD probe and an nRF52840 dongle.\n2. **Build** it ([docs\u002Fbuild\u002Fassembly.md](docs\u002Fbuild\u002Fassembly.md), PDF alongside):\n   - flash the bare board once through four soldered wires on the SWD pads (3V3, SWDIO, SWDCLK, GND);\n   - solder the cell and the charging connector;\n   - bond the six free pods in the flat jig and the base in the pedestal jig;\n   - fold the tail into J1 and close the module;\n   - snap the strap into the pods, lock one end on bar A, tighten through bar B.\n\n   Design details are in [docs\u002Fmech\u002Fmechanical_c.md](docs\u002Fmech\u002Fmechanical_c.md).\n3. **Record**: `python3 host\u002Fneurband_ble.py -o rec.npz`, and in a second terminal\n   `python3 -m analysis collect basic --out data\u002Fs1`.\n4. **Check and train**: `python3 -m analysis report data\u002F*.npz`, `python3 -m analysis train data\u002F*.npz`.\n   Try the whole pipeline without hardware: `python3 -m analysis synth \u002Ftmp\u002Fnb`.\n\n**Safety.** Wear it only while it runs on its own battery. Never connect a charger, USB cable, debugger or\ngrounded instrument while the pads touch skin. This is a research prototype, not a medical device.\n\n## Repository\n\n| Path | What |\n|---|---|\n| `boards\u002Fneurband_c\u002F` | main board: schematic generator (`gen_c_sch.py`), KiCad project, layout scripts |\n| `boards\u002Fneurband_c_flex\u002F` | electrode flex: schematic + parametric PCB generator |\n| `mech\u002Frev_c\u002F` | FreeCAD scripts and STEP for the module, pods, strap path, bonding jigs and fit checks |\n| `firmware_c\u002F` | nRF52832 Zephyr firmware |\n| `host\u002F` | BLE recorder and packet tests |\n| `analysis\u002F` | quality gates, features, baseline models, collection prompts, Meta dataset reader |\n| `sim\u002F` | ngspice AFE simulations and the forearm EMG forward model |\n| `render\u002F` | Blender pipeline for the images (`python3 render\u002Fmake_renders.py`) |\n| `docs\u002F` | design notes, reviews, science, layout and mechanical docs |\n| `.archive\u002F` | older work (a dot-folder, so Backplane's project list skips it): rev A (16 ch, ESP32, 54 × 34 mm) and rev B boards, rev A\u002FB mechanics, the rev C layout scripts |\n| `tools\u002F` | the small Python KiCad schematic generator used for every schematic |\n\n## Status and next steps\n\n- [x] Rev C schematic, main board (DRC 0), flex (DRC 0), mechanics, fit checks on 145\u002F160\u002F180 mm wrists\n- [x] Firmware builds and links for the nRF52832 (Zephyr 4.4.2, 0 warnings, 30 % flash \u002F 94 % RAM); host recorder and analysis pipeline tested on synthetic data\n- [x] Pre-order review and rework: analog coupling\u002Fnoise ([analog_preorder_review.md](docs\u002Freview\u002Fanalog_preorder_review.md)), on-wrist antenna FDTD simulation ([antenna_sim.md](docs\u002Fscience\u002Fantenna_sim.md)), manufacturing and pick-and-place check against the fab's own footprints ([manufacturing_preorder.md](docs\u002Freview\u002Fmanufacturing_preorder.md)), layout owner's review ([sol_preorder_review.md](docs\u002Freview\u002Fsol_preorder_review.md)), assembly walk-through ([assembly.md](docs\u002Fbuild\u002Fassembly.md))\n- [ ] Build two boards; bench gates: shorted-input noise, mains residual, radio-on noise, bias-loop stability\n- [ ] Antenna tuning (π network on the board), BLE throughput on a real link\n- [ ] First week of recordings with the protocol in `docs\u002Fscience\u002Fdata_and_models.md`\n\n## Credits\n\nResearch summary of Meta's work in [docs\u002Fresearch\u002Fmeta_semg_research.md](docs\u002Fresearch\u002Fmeta_semg_research.md).\nHuman model: Blender Studio \"Human Base Meshes\" (CC0). KiCad stock libraries. Meta's datasets referenced here are\nCC BY-NC 4.0.\n","neurband 是一款开源、轻量级的表面肌电信号（sEMG）腕带硬件项目，旨在复现类似 Meta Neural Band 的生物电信号采集能力。它采用 8 通道 ADS1298 24 位生物电前端、nRF52832 蓝牙低功耗模块、干式金电极柔性电路及 3D 打印结构，支持双极 sEMG 与 IMU 多模态同步采集。全部设计基于 KiCad（PCB）、FreeCAD（机械）、Zephyr（固件）和 Python（数据记录与分析），强调可复现性与低成本原型构建。适用于人机交互研究、手势识别模型训练、BCI 教学实验及开源神经接口硬件开发等场景。","2026-11-24 04:44:33","CREATED_QUERY"]